AUTOMATIC RESCUE DEVICE
Passenger lift is required to provide secondary power supply. Means, emergency generator. If, is not available, then the power supply to passenger lift shall be provided via a sub-main circuit. It is advisable that an Automatic Rescue Device (ARD) be incorporated in the lift system to bring the lifts to the nearest floor landing and open its door upon power failure. |
In simple understanding, an ARD is used in elevator application to stop lift at nearest application when electric power cutoff. |
FEATURES: - Very Simple Interface and easy and quick to Install. - Microprocessor Based Sine-wave Output. - Use Sealed Maintenance free (SMF) Battery as per based on lift capacity. |
some text
some text
some text
Electrower's Lift UPS and Lift ARD is a brand in itself, it is very smart and intuitive. It has a lot of features than traditional rescue devices or ARDs. Whenever it detects a power failure, it turns on in 12 seconds and gives power to the motor and allows the lift to reach the nearest floor. Whereas the Lift UPS turns on instantly and the passenger near feels that power failure has occurred. Lift ARD is used for all the 3 phase panels like ADCO and Lift UPS is used for Single-phase panels like ARKEL and Monarch.
RATINGS | 5HP | 7.5HP | 10HP | 15HP |
---|---|---|---|---|
OPERATING DC VOLTAGE | 48V | 48V | 48V | 96V |
NO OF BATTERIES | 4 | 4 | 4 | 8 |
WEIGHT | 20KG | 30KG | 40KG | 50KG |
MOSFET
DSP
PFC
95%
5(Health Maintain Check for 7AH)
0.8
10V (Per Battery) +/- 2%
12V (Per Battery) +/- 2%
10.2V (Per Battery) +/- 2%
15.5V (Per Battery) +/- 2%
15V (Per Battery) +/- 2%
1 +/-2%
440V+/2%
50V+/2%
440V+/-10%
300
520V
1Time
1Time
3 Minutes
2%
3.6/KVA
3Phase-4Wire P,N
120V-280V +/-2%
10V
5V
50Hz +/-3%
5
MOSFET
PWM
220V+/2%
2Phase-2Wire P,N
Sine Wave
50Hz
<10ms
=12ms
0.8 Pf
ARD ON/OFF
Inverter On, Battery Low / High, Overload, Mains Charging On, Mains On
Battery Low, Overload, Charger On, Inverter On
overload, Short Circuit Protection, Over Voltage, Mains Surge and Transient Protection (MOV Varistors), Reverse Polarity of Battery, Over temperature Protection, Under voltage and over voltage Protection
0-50C
<95
IP20
NOTE: Due to continuous improvement in the product and design. These specification may deviate a bit from the actual product, but only in a better way.
Experience of using double battery PWM inverter for home of this brand is very satisfactory. Not only It saves electricity but also carries good backup
Authentic and long life products.Almost every product is durable and user friendly as well.
Good quality product,excellent services,R&D team developed new product in new technologies.
Best quality products, excellent service, good price, reliable products..