LIFT UPS - Automatic Rescue Device

AUTOMATIC RESCUE DEVICE

Electrower's Off Grid MPPT Solar PCU (Power Conditioning Unit) is an intelligent integrated system of Solar MPPT Charger, Grid Charger, Offline InverterWe use innovative MPPT algorithm in our Solar Off-Grid PCU that can simultaneously run the load and charge the battery while extracting maximum power from Solar. Suitable for standard Lead-Acid Batteries, as well as flooded, sealed and Lithium type. Our Solar Off-Grid MPPT PCU stand apart from the rest because of their high-quality design and multiple features we have packed into it to make your life easier.

Long Run Battery

Rugged Reliable

7 Stage Charging For Battery health

Inbuilt Battery Supported

It's all in the details

Pure Sine Wave

Wallmounting Cabinet

Complete Installation Support By Industry Experts

some text 

some text 

How it works?

Electrower's Lift UPS and Lift ARD is a brand in itself, it is very smart and intuitive. It has a lot of features than traditional rescue devices or ARDs. Whenever it detects a power failure, it turns on in 12 seconds and gives power to the motor and allows the lift to reach the nearest floor. Whereas the Lift UPS turns on instantly and the passenger near feels that power failure has occurred. Lift ARD is used for all the 3 phase panels like ADCO and Lift UPS is used for Single-phase panels like ARKEL and Monarch.

Available Models

Technical Specification

Models/Ratings


RATINGS 5HP7.5HP 10HP15HP
OPERATING DC VOLTAGE 48V48V 72V72V
NO OF BATTERIES 44 66
WEIGHT20KG30KG40KG50KG

Lift UPS-Automatic Rescue Device 

Microcontroller PFC Based Charger 


Switching Element

MOSFET


Control Type

DSP


Type of Charger 

PFC


Efficiency

95%


Battery Charging Stages 

5(Health Maintain Check for 7AH)


Power Factor

0.8


Battery


Low Cut Off

10V (Per Battery) +/- 2%


Low Cut Off Recovery 

12V (Per Battery) +/- 2%


Low Buzzer

10.2V (Per Battery) +/- 2%


High Cut Off

15.5V (Per Battery) +/- 2%


High Cut Off Recovery 

15V (Per Battery) +/- 2%


Charging current by Grid

1 +/-2%


Output


Output @ No Load

220V+/2%


Output Frequency

50V+/2%


Output @ Full Batt to Low Batt

220V+/-10%


Output Low Cut 

150


Output High Cut 

260


Output Low Retry

1Time


Output Short Circuit 

1Time


UPS Backup Time

2 Minutes 


No Load Battery Current

2%


Overload

3.6/KVA


Mains


No. of Phase

1Phase-2Wire P,N


Voltage range

120V-280V +/-2%


Mains Low recovery range 

10V


Mains High recovery range 

5V


Frequency range 

50Hz +/-3%


Battery Charging Stages 

5


Inverter


Switching Element

MOSFET


Control 

PWM


Output Voltage  

220V+/2%


Phase

1Phase-2Wire P,N


Output Waveform

Sine Wave


Frequency

50Hz


Changeover UPS to Mains

<10ms


Changeover Mains to UPS

<10ms


Output Power factor 

0.8 Pf


Switch 

UPS ON/OFF


Indication

Inverter On, Battery Low / High, Overload, Mains Charging On, Mains On


Alarm

Battery Low, Overload, Charger On, Inverter On 


Protection 

overload, Short Circuit Protection, Over Voltage, Mains Surge and Transient Protection (MOV Varistors), Reverse Polarity of Battery, Over temperature Protection, Under voltage and over voltage Protection 


Operating Temp 

0-50C


Operating Humidity 

<95


Protection Class

IP20



NOTE: Due to continuous improvement in the product and design. These specification may deviate a bit from the actual product, but only in a better way. 

Beloved Google Reviews