Lithium UPS

Lithium UPS

It's all in the details

How it works?

Lithium UPS

Available Models

Technical Specification

Models/Ratings



MODELS 1KVA2KVA3KVA5KVA
OPERATING DC VOLTAGE 51.2V51.2V 51.2V51.2V
BATTERY CAPACITY  2040 60100
WATTAGE 1024W2048W3072W5120W
SPV OPEN CIRCUIT VOLTAGE RANGE(Min-Max)72-18072-18072-18072-180
MAX SPV POWER1KW2KW3KW5KW
SWITCHING ELEMENTIGBT DISCRETEIGBT MODULEIGBT MODULEIGBT MODULE
CHARGING CURRENT BY GRID10A+/-2%15A+/-2%
20A+/-2%
20A+/-2%
OVERLOAD(Amps)3.5Amps7Amps
11Amps
18Amps
OVERLOAD(Watt)
800W1600W2400W4000W
SWITHCING ELEMENTMOSFETMOSFET
MOSFET
IGBT


Lithium UPS 

SPV Parameters


Compatible SPV Panels

36/60/72


MPPT Based Charge Controller


Controller

DSP


Efficiency

>95%


Battery Charging Stages 

3(Soft Start, Boost, Absorption)


Battery


Low Cut Off

40V (Per Battery) +/- 2%


Low Cut Off Recovery 

50V (Per Battery) +/- 2%


Low Buzzer

41V (Per Battery) +/- 2%


High Cut Off

56V (Per Battery) +/- 2%


High Cut Off Recovery 

55.5V (Per Battery) +/- 2%


Boost Charging Volt by SPV (TUB)

55V (Per Battery) +/- 2%


Boost Charging Volt by Grid (TUB)

54V (Per Battery) +/- 2%


No Load Battery Current

0.02%


Output


Output @ No Load

230+/-2%


Output Frequency

50Hz +/-2%


Output Low Retry

1Time


Output Short Circuit 

1Time


Grid


No of Phase

1Phase-3Wire P, N, E


Voltage Range(Inverter Mode)

100V-280V +/-2%


Voltage Range (UPS Mode)

175V-255V +/-2%


Frequency Range

45V-55V +/-2%


Display


Display 

Alphanumeric - 20X4 LCD

Output(Inverter) - Voltage, Current, Power and Frequency

Input(Grid) - Voltage and Frequency 

Solar - Voltage, Current, Power and Energy (Optional)

Battery - Voltage, Charging Current


Parameters

Status/Faults - Inverter Status, Mains Status, Charge Status, Solar Status and Battery Status/Charging Stages


Battery Charging Stages 

5


Inverter


Output Voltage  

230V+/2%


Phase

1Phase-3Wire P,N, E


Output Waveform

Digitally Filtered Pure Sine Wave


Frequency

50Hz +/-2%


Changeover Mains to Inverter

<10ms


Output Power factor 

0.8 Pf


Overload Retry

3 Times


Switches

System ON/OFF, Setting Configuration 


Alarm

Battery Low, Overload, Charger On, Inverter On, Solar Charger On 


Protection 

overload, Short Circuit Protection, Over Voltage, Mains Surge and Transient Protection (MOV Varistors), Reverse Polarity of Battery, Over temperature Protection, Under voltage and over voltage Protection 


Operating Temp 

0-50C


Operating Humidity 

95


Protection Class

IP20



NOTE: Due to continuous improvement in the product and design. These specification may deviate a bit from the actual product, but only in a better way. 