Online PCU

Online PCU

Fast Charging

Inbuilt Solar PWM Charger

Multiple Battery Selection

Industrial Modbus Megatech Comm

It's all in the details

Galvanic Isolation

Built-in Energy Meter

Safety & Protections

How it works?

Online PCU

Available Models

Technical Specification

Models/Ratings


RATINGS 1KVA COPPER1KVA 2KVA2.5KVA COPPER 3KVA 5KVA 5KVA 7.5KVA 7.5KVA10KVA10KVA15KVA
OPERATING DC VOLTAGE 12V24V 24V24 48V 48V 96V 96V 120V120V180V240V
MAX SPV SUPPORTED 1KW1KW 2KW2.5KW 3KW 5KW 5KW 7.5KW 7.5KW10KW10KW15KW
PV VOC 18-45V36-90V 36-90V36-90V 72-180V 72-180V 144-360V 144-360V 180-450V180-450V270-450V360-600V
OUTPUT VOLTAGE 230V +/-2%



OVERLOAD AMPS3.6A3.6A7A8.7A10.5A17.4A17.426A26A34.8A34.8A52.2A
OVERLOAD WATTAGE800W800W1.6KW2KW2.4KW4KW4KW6KW6KW8KW8KW12KW


Online PCU

Switching Element

IGBT


Controller

Digital Signal Processor dsPIC


Efficiency

> 95%


Battery Charging Stages

5 (Softstart, Boost, Absorbtion, Float, Equalise)


Battery


Low Cut Off / Recovery

10.5V / 11.5V (Per Battery) +/- 2%


Low Cut Off Alarm

10.7V (Per Battery) +/- 2%


High Cut Off / Recovery

15.5V / 15.0V (Per Battery) +/- 2%


Boost Charging Voltage by Grid (Tubular)

14.5V (Per Battery) +/- 2%


Boost Charging Voltage by Grid (SMF)

+/- 2%


Charging Current by Grid

10A +/- 2%


Output (Inverter)


Output @ No Load

230V +/- 2% 1 Phase 3 Wire P,N,E


Output Frequency

50 Hz +/- 2%


Output Low/Shortcircuit Retry

1 Time


No Load Current (NLC)

2%


Display Parameters


Display

16X2 Display (1KVA Models)/ 20X4 LCD Alphanumeric (2KVA Above)


Inverter Display

Voltage, Current, Power, Energy and Frequency


Solar Display

Voltage, Current, Power, Energy Generated (Cumulative)


Mains Grid Display

Voltage and Frequency


Battery Display

Voltage and Charging Current


Status / Fault Display

Inverter Status, Mains Status, Charger Status, Battery Status, Charging Status, Solar Status, Solar Charger Status


Inverter


Switching Element

MOSFET & IGBT


Output Waveform

Digital Filtered Pure Sine Wave


Overload Retry

3 Times


Switch

System On/Off, Four Micro Switches (Enter, Back, Up, Down) to access and navigate through the settings MENU. Download the detailed brochure to understand all settings.


Indication

UPS, Mains, Charging (Solar & Mains) , Battery, Overload


Alarm

Inverter On/Off, Mains Charger On, Solar Charger On, Overload, Battery Low


Protection

Overload, Short circuit, Over voltage, Under Voltage, Mains Surge and Transient by MOV and Varistors, Reverse Polarity of Battery, Over Temperature, Solar Reverse, SPV Surge


Cooling

Forced Air Cooling (Temperature Controlled)


Remote Monitoring

RS232, RS485, GSM / GPRS Remote Monitoring (Optional)


Operating Temperature

0-50 Degree Celsius


NOTE: Due to continuous improvement in the product and design. These specification may deviate a bit from the actual product, but only in a better way.