Solar Off Grid PWM PCU

CLEAN & GREEN SOLAR POWER BACKUP

Electrower's Off Grid PMW Solar PCU (Power Conditioning Unit) is an intelligent integrated system of Solar PWM Charger, Grid Charger, Offline InverterWe use innovative PWM algorithmin our Solar Off-Grid PCU that can simultaneously run the load and charge the battery while extracting power from Solar, although it is less efficient than MPPT technique of charging. Suitable for standard Lead-Acid Batteries, as well as flooded, sealed and Lithium type. Our Solar Off-Grid PWM PCU stand apart from the rest because of their high-quality design and multiple features we have packed into it to make your life easier.

Alphanumeric Display

Low Voltage Charging

Prioritize Solar For Excellent Usage

Pure Sine Wave Output

It's all in the details

Inbuilt Solar PWM Charger 50-60Amps

Save Money and Clean Environment

Advanced DSP Based Technology

INVERTER SWITCH

Push to On and push to Off switch. Whenever this switch is On, the Inverter will automatically turn on, until any unavoidable fault occurs. If the fault is recovered, the inverter will automatically switch on. 


16X2 ALPHANUMERIC DISPLAY

display to show all parameters related to Inverter, Battery and Mains. Also, display the system internal parameters and status. It helps the electrician and service engineer to easily diagnose the problem.


LED INDICATION

5 LEDs, UPS, Charging, Mains, Battery, Overload are given to easily identify the state of the system and diagnose the fault. 


INVERTER SWITCH

Push to On and push to Off switch. Whenever this switch is On, the Inverter will automatically turn on, until any unavoidable fault occurs. If the fault is recovered in case of static bypass, the inverter will automatically switch on. 


20X4 ALPHANUMERIC DISPLAY

Big display to show all parameters related to Inverter, Battery and Mains. Also, display the system internal parameters and status. It helps the electrician and service engineer to easily diagnose the problem.


CONFIGURATION SWITCHES

UP, DOWN, SELECT, BACK switches are used to navigate into the menu, for various settings related to the system. 


LED INDICATION

5 LEDs, UPS, Charging, Mains, Battery, Overload are given to easily identify the state of the system and diagnose the fault. 


INVERTER SWITCH

Push to On and push to Off switch. Whenever this switch is On, the Inverter will automatically turn on, until any unavoidable fault occurs. If the fault is recovered in case of static bypass, the inverter will automatically switch on. 


20X4 ALPHANUMERIC DISPLAY

Big display to show all parameters related to Inverter, Battery and Mains. Also, display the system internal parameters and status. It helps the electrician and service engineer to easily diagnose the problem.


CONFIGURATION SWITCHES

UP, DOWN, SELECT, BACK switches are used to navigate into the menu, for various settings related to the system. 


LED INDICATION

5 LEDs, UPS, Charging, Mains, Battery, Overload are given to easily identify the state of the system and diagnose the fault. 


How it works?

Electrower's Solar Off-Grid PWM PCU consists of a PWM Solar Charge Controller, Offline Inverter, and a Grid Charger all in an integrated form. The Off-Grid Solar PCU is designed to maximise the use of Solar Power. When the batteries are charged from Solar, the Smart PCU disconnects Grid/Mains/DG and let the Inverter/Load run on Solar. It let user enhance use of solar power, also as per the user preferences it has twpmodes:

  • Smart Mode (PCU gives priority to solar, second priority to the grid and third priority to the batteries in smart mode). Recommended in Semi-Urban Area, where power cut is less than 2 hours.
  • Hybrid Mode (In this mode PCU works well with solar as well as batteries. Grid charging only takes place when solar power is not sufficient to charge the batteries). Recommended in Rural Area, where power cut is more than 2-3 hours.

Available Models

SUNRAY E-SINE

  • Available from 850VA/12V to 5KVA/48V Models.
  • Can be turned ON by Mains, It can turn on battery from 0 volts. 
  • It is highly recommended for Home use & Shops.

Technical Specification

Models/Ratings

MODEL/RATINGS 1150/850VA 1550/1KVA2150/1.5KVA 2550/2KVA 3150/2.5KVA 3550/3KVA 4550/4KVA 5550/5KVA
OPERATING DC VOLTAGE 12V 12V24V 24V 24V 48V 48V 48V
MAX SPV SUPPORTED 650W 800W1200W 1600W 1600W 2400W 3200W 3200W
PV VOC 16-30V 16-30V
32-60V
32-60V
32-60V
32-60V
64-120V
64-120V
MAX BATTERY CURRENT50A60A50A60A60A50A60A60A
RECOMMENDED PANEL CELL36 CELLS36 CELLS60/72 CELLS60/72 CELLS
60/72 CELLS
60/72 CELLS
60/72 CELLS
60/72 CELLS
OUTPUT VOLTAGE
220V / 230V +/-2%
OVERLOAD AMPS3.1A3.6A5.5A7.3A9.1A10.9A13.9A17.4A
OVERLOAD WATTAGE680W800W1200W1600W2000W2400W3200W4000W
DC DISCHARGING AMPS55A67A55A67A83A55A67A83A

PWM Based Charge Controller

Switching Element

MOSFET


Controller

Digital Signal Processor dsPIC


Efficiency

> 95%


Battery Charging Stages

5 (Softstart, Boost, Absorbtion, Float, Equalise)


Battery


Low Cut Off / Recovery

10.5V / 11.5V (Per Battery) +/- 2%


Low Cut Off Alarm

10.7V (Per Battery) +/- 2%


High Cut Off / Recovery

15.5V / 15.0V (Per Battery) +/- 2%


Boost Charging Voltage by Grid (Tubular)

14.5V (Per Battery) +/- 2%


Boost Charging Voltage by Grid (SMF)

+/- 2%


Charging Current by Grid

10A +/- 2%


Output (Inverter)


Output @ No Load

220V / 230V +/- 2% 1 Phase 3 Wire P,N,E


Output Frequency

50 Hz +/- 2%


Output Low/Shortcircuit Retry

1 Time


No Load Current (NLC)

2%


Display Parameters


Display

16X2 Display (Upto 3KVA Models)/ 20X4 LCD Alphanumeric (4KVA & 5KVA)


Inverter Display

Voltage, Load % and Frequency


Solar Display

Voltage, Current, Power


Mains Grid Display

Voltage and Frequency


Battery Display

Voltage and Charging Current


Status / Fault Display

Inverter Status, Mains Status, Charger Status, Battery Status, Charging Status, Solar Status, Solar Charger Status


Inverter


Switching Element

MOSFET


Output Waveform

Digital Filtered Pure Sine Wave


Overload Retry

3 Times


Switch

System On/Off, Hybrid / Smart Switch, Inverter / UPS Mode Switch


Indication

UPS, Mains, Charging (Solar & Mains), Battery, Overload


Alarm

Inverter On/Off, Mains Charger On, Solar Charger On, Overload, Battery Low


Protection

Overload, Short circuit, Over voltage, Under Voltage, Mains Surge and Transient by MOV and Varistors, Reverse Polarity of Battery, Over Temperature, Solar Reverse, SPV Surge


Cooling

Forced Air Cooling (Temperature Controlled)


Operating Temperature

0-50 Degree Celsius


NOTE: Due to continuous improvement in the product and design. These specification may deviate a bit from the actual product, but only in a better way.